Angle reducing valve weighing 3,5 tons

Another of our interesting realizations is the control valve VA2012.BMK, which will reduce the steam pressure from 43 bar to 5.5 bar, with a maximum flow capacity of 300 t/h. The pressure reducing valve has an angle design with an inlet diameter of 18″ (DN450) and an outlet diameter of 32″ (DN800). Five reduction stages of the multicage are used to keep the maximum noise level below 85 dB(A). Pressure balancing by a pilot plug allows reduction of the necessary control force. The valve is controlled by a single-acting piston actuator LPP of our own production. Emergency closing is ensured by a spring inside the actuator. Precise regulation is provided by an electro-pneumatic positioner supported by pneumatic booster, which ensures a quick response to the requirements of the control system.